Only with Wet & Dry models equipped with a mechanical and/or electrical safety float system and filters specifically designed for liquid collection. Models without a safety float and suitable filters must never be used to collect liquids. The same machine can handle both dry materials and liquids only if it is designed for wet and dry applications or fitted with the right accessories and configuration for both. After vacuuming liquids, always inspect the filter and replace it if necessary. See our guide to wet and dry vacuum cleaners for more detail.
Voltage configurations must be specified at the time of order. Any change afterward requires replacing electrical components and often the electric motors as well. If you need a single-phase industrial vacuum for a specific supply, tell your sales representative before ordering. Read why power matters when choosing a vacuum for the basics.
Availability varies depending on the model and current inventory. We can provide 115V stainless steel wet & dry vacuum solutions, subject to stock availability or production lead times. Check live stock status in our electric vacuums and pre-separators range, or contact our sales team for current availability. Our guide to choosing a wet and dry vacuum helps you compare models first.
For single-phase machines, a maximum hose length of 16 to 33 feet (5 to 10 meters) is generally recommended to avoid performance loss. Longer distances require dedicated technical sizing. Browse our flexible hoses or read the industrial vacuum cleaner buying guide.
Hose diameter depends on vacuum power, motor type, the amount of material being collected, material density, and the specific application. Proper sizing should be evaluated during the quoting phase with your sales representative to ensure optimal performance and proper air velocity. Explore our flexible hoses and the accessory catalog (PDF).
Container capacities range from approximately 15 liters (4 gallons) to more than 1,000 liters (264 gallons), depending on the model. Empty the container when it reaches its maximum fill level or when suction performance begins to decline. Compare models in our portable vacuum systems range, or see the 4 essential components of an industrial vacuum.
It depends on the machine’s power and configuration. Standard units are designed for a single operator. Multi-user applications require proper engineering, including multiple inlet manifolds and adequate power capacity. This is the typical case for centralized vacuum systems; our central vacuum system guide explains how they are sized.
Lead times depend on the model and configuration. Some standard products are available from stock, while others are built to order. Our Sales Department can provide up-to-date availability and lead times for the electric vacuums and pre-separators and pneumatic vacuums kiosk ranges.
The standard warranty period is 24 months from the date of delivery, unless otherwise specified by contractual agreement. Components subject to normal wear and tear, as well as damage resulting from improper use, are not covered. For questions about a specific order, contact Delfin Industrial.
All Delfin industrial vacuums and accessories are designed and manufactured in Italy, where the metric system is the standard for engineering and manufacturing. As a result, dimensions follow European standards and production tolerances. To support our international customers, our documentation and marketing materials are provided in both metric and imperial units. See the product line brochure (PDF) or the electric vacuums and pre-separators catalog pages.
The code beginning with “V” on the quotation is the commercial sales code, or the internal configuration used for the proposal. The code shown on the vacuum itself is the machine model code. The two differ because they belong to different coding systems, one commercial and one product-specific. The product line brochure (PDF) lists the current range; your sales representative can match the codes for you.
A certified vacuum is required when handling hazardous, combustible, toxic, or regulated dusts, or when operating in regulated environments. The selection should be based on your site’s risk assessment. Start with our explosion proof vacuums and the solutions for hazardous locations or ordinary locations with combustible dust. The article on NRTL-certified vacuums for combustible dust explains the certification side.
Use ETL-Intertek certified models, or appropriately configured units with antistatic components. Proper grounding of both the vacuum system and all accessories is essential. See our explosion proof vacuums, including the inert industrial vacuum cleaners and pneumatic vacuums, and read how to prevent combustible dust explosions.
ATEX certification is a European directive governing equipment intended for use in potentially explosive atmospheres. It is required whenever combustible dusts, gases, or vapors are present. If you are in the North American market, make sure you are using a locally certified vacuum. Contact us for more information, or watch our ATEX video. Certified options are in our explosion proof vacuums range.
An ACD configuration is required when combustible or explosive dusts are present. It is intended for non-classified environments where a risk assessment conducted with the Sales team identifies the potential for combustible dust handling in non-certified areas. Read more about solutions for hazardous locations or ordinary locations with combustible dust, or see an ACD dust collector example.
An industrial vacuum cleaner is built to pick up dust and heavier material directly from the floor or a surface. It has higher water lift and lower airflow, enough strength to defy gravity. A dust collector handles light, fine material and airborne dust. It moves a high volume of air with lower water lift to trap those particles. Compare our portable vacuum systems and dust collectors, or read the full comparison on our blog.
Removing airborne dust requires an industrial dust collector, not a vacuum. A vacuum cleaner is designed for point-source collection. A dust collector continuously filters the ambient air and captures fine particles before they settle or are inhaled, with adequate airflow capacity and a dedicated capture system. The right model is sized to the room volume and the amount of dust generated. See our dust collectors and the article on removing airborne dust in your industry.
This is not recommended without a technical evaluation. Dust collectors are generally not designed for manual operation with a flexible hose unless specifically configured for that purpose. If you need both functions, review our dust collectors with our sales team, or choose a portable vacuum system for point-source cleaning.
Some single-phase models are available in a 115V configuration. Availability depends on the motor range and the required power rating, and must be confirmed at the time of order. See the ZEFIRO EV AP 420 115 Volt ACD and the full range of dust collectors.
A brushless model uses a single-phase motor without carbon brushes, with an average service life of up to 20,000 hours. It does not require brush replacement and can operate continuously for 2 to 3 hours without strain. It is designed to reduce maintenance and improve reliability. See our single-phase industrial vacuum cleaners or watch the brushless motor video.
Single-phase vacuums suit intermittent use and light-to-medium-duty applications. Three-phase vacuums are designed for continuous operation, greater long-term durability, and demanding industrial environments. Compare our single-phase and three-phase industrial vacuum cleaners, and read continuous duty vs. intermittent duty.
Bypass motors typically provide approximately 1,200 to 1,400 operating hours. Brushless motors can reach up to 20,000 operating hours. Three-phase side-channel blower motors can exceed 20,000 operating hours when properly maintained. See the three-phase vacuums and single-phase vacuums, or watch the motor life video.
On average, every 700 to 800 operating hours, depending on workload. Preventive inspections and proper maintenance can extend motor life to approximately 1,300 to 1,400 operating hours. Original brushes and motors are available as replacement parts; the brush replacement video shows the procedure.
Some models allow individual motors to be switched on or off separately. Others can be equipped with an inverter for variable power control, provided this configuration was selected at the time of order. This is common on three-phase vacuums and on the suction units for central vacuum systems. Watch the power adjustment video.
Disconnect the machine from the power supply and carefully follow the technical instructions in the motor replacement manual. Use only original Delfin replacement parts to ensure safety and performance. Find them in our replacement parts and watch the motor replacement video.
Class L or M polyester filters suit general dust applications. HEPA and ULPA filters are designed for very fine particles. Antistatic filters are required for conductive dusts or combustible dust applications. PTFE and Nomex filters are recommended for high-temperature applications or moist dust. Browse our industrial vacuum filters or read the filter options guide.
Review the material safety data sheet and classify the dust as L, M, or H. Once the dust class is known, select a filter that complies with the relevant standards and your application requirements. See the filters available, or our guide to HEPA industrial vacuums.
A Class L filter provides a filtration efficiency of at least 99%, with a maximum dust penetration of 1%. It complies with EN 60335-2-69 requirements for low-risk dust and ensures adequate control of emissions in the exhaust air. See the filters for Delfin vacuums.
A Class M filter provides a higher level of filtration, with a minimum efficiency of 99.9% and a maximum penetration of 0.1%. Under EN 60335-2-69, it also requires airflow monitoring and filter clogging indicators to ensure performance is maintained over time. Explore the filters range or read the filter options guide.
No. Filters must not be washed. If they become saturated, replace them with original replacement filters to ensure efficiency and safety. HEPA and ULPA filters are not washable either and should generally be replaced every 12 months, or sooner depending on operating conditions and usage. See original replacement filters and our HEPA vacuum guide.
The right interval depends on the application and the type of dust collected. In industrial environments, inspect filters regularly and replace them whenever performance noticeably drops or per your preventive maintenance schedule. Typical intervals are every 3, 6, or 12 months. Routine maintenance includes regular cleaning with a manual or automatic filter cleaning system, plus periodic checks of the filter’s integrity. Order replacement filters and watch the filter maintenance video.
Common signs are reduced suction performance, higher readings on the vacuum gauge or differential pressure gauge, increased motor noise, higher operating temperature, and increased current draw. The vacuum gauge gives an objective indication of filter loading. If the filter is saturated, clean it or replace it. See our filters and the filter maintenance video.
The DUSTOP system is a semi-automatic filter cleaning device that uses the vacuum generated by the motors. When the inlet is closed while the motors are running, vacuum pressure rises inside the filter chamber. Opening the flap lets incoming air detach dust from the filter, and the removed dust falls into the collection container. See the DUSTOP video and our filters.
Disposable collection bags can be used on compatible models. Cyclonic pre-separators are recommended to reduce the load on the main filter and extend its service life. See all pre-separators, filters and accessories.
Connections can be made through automatic start kits, remote relays, or remote-control systems. Verify electrical and pneumatic compatibility with the equipment before installation. See solutions for production lines, the accessories for industrial vacuuming, and the accessory catalog (PDF).
We recommend monthly inspections of key components such as motors, daily cleaning, semiannual replacement of filters and gaskets, and a complete machine overhaul every 12 to 24 months. Spare parts are in our replacement parts. See also 4 ways to improve your dust collection system.
Replace filters regularly, use the right accessories, avoid running the machine with the suction inlet blocked, and follow the recommended duty cycles. Original filters and accessories help keep the motor within its design limits. Read the filter and cleaning systems guide.
Verify that power is available and that the voltage matches the machine nameplate. Check the power outlet, power cord, main switch, emergency stop button, fuses, and thermal protection devices. Turn the vacuum off, disconnect it, and wait at least 15 minutes so the motor cools and the thermal protection resets. Check that the filter and hose are not clogged. If the problem persists, consult the technical manual or contact customer service with the vacuum model and serial number. Electrical checks should be done by qualified personnel.
In most cases the thermal protection has tripped because of a clogged filter, a blocked hose, or operation under overload. Check the suction circuit for obstructions and replace the filter if necessary. A qualified technician can compare the machine’s current draw with the nameplate values and inspect the fuses. Restart the vacuum only after the motor has fully cooled down. Read the buying guide to review duty and sizing.
The most common causes are a saturated filter, a blockage in the hose or accessories, or operation with the suction inlet partially restricted. Verify airflow, replace the filter if necessary, and let the machine cool for at least 15 minutes before restarting. See the filter options and cleaning systems guide.
Typical sound levels range from 75 to 85 dB, depending on the model. Unusual noise may indicate motor wear, filter or gasket deterioration, or foreign material in the turbine, and should be investigated by a qualified technician. Check replacement parts or contact our team.
Switches and indicators must be repaired strictly in accordance with Delfin technical instructions and only after disconnecting the machine from the power supply. When replacement is required, use only original Delfin spare parts. For our ETL-Intertek certified models, repairs must be carried out exclusively by Delfin, as the certifying body, or by authorized personnel with formal approval and the appropriate certification for certified equipment. If adequate expertise is not available, contact your sales representative.
The Tecnoil pump is not repairable and must be replaced entirely with an original replacement part. The replacement pump is covered by a 12-month warranty. Before replacing it, also inspect any fuses in the control head and make sure they are not blown or damaged. See our oil & chips industrial vacuum cleaners and the solutions for CNC machinery.